Hi,
I just installed a trial version of Alert Manager 2007 to my development system. It successfully deployed to the web apps I chose, and the SharePoint Central Admin pages. YAY.
The development environment is a single server farm, 32-bit WSS 3.0 / MOSS 2007 SP2.
Now I am testing and can't seem to get an alert created at all. When I go to my test site and choose "Manage My Alerts" which resides on the web application to which Alert Manager is installed, I get to the Alert Manager "Manage Alerts" page. I have no filters, and I go to New -> Add Alert.
I have turned off SharePoint's "friendly" error messages as detailed in the ExCM help to reveal the following error:
|
|
|
The file '/_controltemplates/SPSolutions/AlertManager/InputFormSectionAlertSendConfirmation.ascx' does not exist. at System.Web.UI.Util.CheckVirtualFileExists(VirtualPath virtualPath) at System.Web.Compilation.BuildManager.GetVPathBuildResultInternal(VirtualPath virtualPath, Boolean noBuild, Boolean allowCrossApp, Boolean allowBuildInPrecompile) at System.Web.Compilation.BuildManager.GetVPathBuildResultWithNoAssert(HttpContext context, VirtualPath virtualPath, Boolean noBuild, Boolean allowCrossApp, Boolean allowBuildInPrecompile) at System.Web.Compilation.BuildManager.GetVPathBuildResult(HttpContext context, VirtualPath virtualPath, Boolean noBuild, Boolean allowCrossApp, Boolean allowBuildInPrecompile) at System.Web.UI.BaseTemplateParser.GetReferencedType(VirtualPath virtualPath, Boolean allowNoCompile) at System.Web.UI.BaseTemplateParser.GetUserControlType(VirtualPath virtualPath) at System.Web.UI.MainTagNameToTypeMapper.ProcessUserControlRegistration(UserControlRegisterEntry ucRegisterEntry) at System.Web.UI.BaseTemplateParser.ProcessDirective(String directiveName, IDictionary directive) at System.Web.UI.TemplateControlParser.ProcessDirective(String directiveName, IDictionary directive) at System.Web.UI.PageParser.ProcessDirective(String directiveName, IDictionary directive) at System.Web.UI.TemplateParser.ParseStringInternal(String text, Encoding fileEncoding) |
|
When I look at the server at c:\program files\common files\microsoft shared\web server extenstions\12\TEMPLATE\CONTROL TEMPLATES\SPSolutions\AlertManager (I hope this is the correct location) I see a number of files beginning with the string "InputFormSectionAlert" but there's no file entitled "InputFormSectionAlertSendConfirmation.ascx".
Did I do something incorrectly or should the file exist elsewhere on the server's file system?
Please let me know what other information you need.